JavaScript Disabled

This site requires JavaScript Enabled to function properly. Please enable JavaScript or use a different browser that has JavaScript enabled.

Buying For Victoria
Skip to main content

Display Tender RFT 63/2852/16 

This page displays the details of a tender.

Construction of Seymour SPS 01 Rising Main
Issued By Goulburn Valley Water
Request for Tender
Status:
Open
Number:
RFT 63/2852/16
Contract Number
63/2852/16
UNSPSC
Public Utilities and Public Sector Related Services

Enquiries 

Contacts

Description 

Goulburn Valley Water seeks a suitable contractor for the construction of the SPS01 rising main and associated works as shown on the drawings accompanying this specification.

The scope of works is as follows:

• Project management and preliminaries; including site establishment, mobilisation and demobilisation , setting out the works, approvals and permits.
• Construction of the new DN450 rising main via both open trench and trenchless methods within the denoted allowable works corridor as shown on the drawings, from the Oak Street pump station site to the

Seymour Wastewater Management Facility (WMF) (approx. 3,225 m in length) including:

▪ Site establishment, mobilisation and demobilisation, setting out the works, approvals and permits, establishment of protection zones for trees, service proving and traffic management
▪ Thrust restraint
▪ Isolation valves, air valves, scour valves and associated pits, surface boxes and markers
• Construction of 100m (approx.) of DN250 duplication at approx. CH 3000 including 5 gate valves along the DN250 duplication and 2 gate valves along the main DN450 pipeline as shown on the drawings
• Reconfiguration of the separate SPS16 rising main, including slip-lining a new OD63 rising main through the existing Tarcombe Road rising main and appropriate all fittings and appurtenances
• Minor modification to the concrete access point on the driveway at the Oak Street Pump Station
• Grouting of dual existing AC mains at road crossings
• Supply of equipment as necessary for the completion of the contract works
• Adherence to all requirements documented within:
▪ Conditions of planning permit by Mitchell Shire Council
▪ Cultural Heritage Management Plan as approved by Taungurung Clans Aboriginal Corporation
▪ Conditions of works as set out by Goulburn Broken Catchment Management Authority as well as those forming Works on Waterways approval
▪ Conditions of Flora and Fauna Guarantee Act Permit by DELWP

Specification Documents 

You must be logged in to download documents.
  •    63-2852-16 - Contract Specification
    • Version 1 (13/09/2021)
    • Available by Download   (1 MB)
  •    63-2852-16 - Technical Specification
    • Version 1 (13/09/2021)
    • Available by Download   (1 MB)
  •    63-2852-16 - Tender Booklet
    • Version 1 (13/09/2021)
    • Available by Download   (401 KB)
  •    63-2852-16 - Drawings
    • Version 1 (13/09/2021)
    • Available by Download   (18 MB)
  •    Appendix A - Factual Geotechnical Investigation Report - DOC21 62211
    • Version 1 (13/09/2021)
    • Available by Download   (2 MB)
  •    Appendix A1- Supplement to the MRWA Edition of WSAA Gravity Sewer Code - DOC21 62210
    • Version 1 (13/09/2021)
    • Available by Download   (526 KB)
  •    Appendix B - Temporary Lease Area Plan (Work Zones) - DOC 21 62424
    • Version 1 (13/09/2021)
    • Available by Download   (99 KB)
  •    Appendix B1 - Endorsed Planning Permit - DOC21 62212
    • Version 1 (13/09/2021)
    • Available by Download   (2 MB)
  •    Appendix B1-1 - Planning Permit Extension - DOC21 62443
    • Version 1 (13/09/2021)
    • Available by Download   (321 KB)
  •    Appendix B2 -Flora and Fauna Guarantee Act Permit - DOC21 62442
    • Version 1 (13/09/2021)
    • Available by Download   (968 KB)
  •    Appendix B3 -1 - Works on Waterway Permit - DOC21 62214
    • Version 1 (13/09/2021)
    • Available by Download   (591 KB)
  •    Appendix B4 -1 - CHMP Approval Letter - DOC21 62215
    • Version 1 (13/09/2021)
    • Available by Download   (310 KB)
  •    Appendix B4 - 2 - CHMP with RAP approval -DOC21 62216
    • Version 1 (13/09/2021)
    • Available by Download   (15 MB)
  •    Appendix C - ICN Contestability Assessment Letter - DOC21 62632
    • Version 1 (13/09/2021)
    • Available by Download   (139 KB)
  •    ADDENDUM #1 - Contract No 63 2852 16 - Construction of Seymour SPS01 Rising Main
    • Version 1 (16/09/2021)
    • Available by Download   (45 KB)

Responses 

You must be logged in to submit a response.
Tender closes at 19 October 2021 02:00 PM
Click here to submit an electronic response

Briefings 


A briefing session will be held at Seymour SPS01, Oak Street, Seymour, Vic, Australia, 3660 on 23 September 2021 09:00 AM.
A site visit is a pre-requisite to submission and consideration of a bid.
Registration closes on 20 September 2021 05:00 PM


A briefing session will be held at SPS01 Pump Station, 74 Oak Street,, Seymour, Vic, Australia, 3660 on 23 September 2021 01:00 PM.
A site visit is a pre-requisite to submission and consideration of a bid.
Registration closes on 20 September 2021 05:00 PM

Forum 

Forum posts cannot be posted after 12 October 2021 04:30 PM

The online forum provides a place to comment and obtain further clarification if needed.
In order to submit or comment on a post you must be logged-in and have downloaded the documents.
Comments cannot be posted after 12 October 2021 04:30 PM.

  Link To Forum

Please note that the use of the forum for supplier self-promotion is unacceptable and may result in the supplier having their account suspended. Such posts shall not be responded to or published on the forum.